English

العربية
Français
Pусский
Español
Português
Italiano
ไทย
Polski
Melayu
Bahasa indonesia
românesc
How does the dosing solenoid valve work?
You are here: Home » News » How does the dosing solenoid valve work?

How does the dosing solenoid valve work?

Publish Time: 2023-05-08     Origin: Site

A solenoid valve is a valve that is opened or closed by electromagnetic force. For use on gas or liquid routes. There are many structures and types, but the principle of action is basically the same.


  • What is the working principle of the solenoid valve?

  • What are the specific classifications of solenoid valves?

  • What is the function of the solenoid valve?


What is the working principle of the solenoid valve?

Inside the solenoid valve is a closed cavity. The center of the cavity is the piston and the two sides of the cavity are two electromagnets. Once the electromagnet coil is excited, the valve body is attracted towards the electrified electromagnet. There are through holes connected to different oil lines, so that part of the oil outlet hole can be selected to open by controlling the movement of the valve body; Since the oil inlet hole is in a normally open state, the movement of the valve body causes the hydraulic oil to enter various oil outlet pipes. The pressure of the oil presses on the piston of the cylinder, which in turn presses the piston rod, which drives the mechanism. Using this principle, the function of controlling the mechanical movement can be realized by controlling the switching on and off of the electromagnet.


What are the specific classifications of solenoid valves?

1. Working principle of direct acting solenoid valve: When excited, the solenoid coil generates an electromagnetic force, which directly attracts the valve core and displaces the valve core. When the current is switched off, the electromagnetic force disappears and the valve core is reset by the spring.

2. The working principle of distributed direct acting solenoid valve: It is a combination of direct acting and pre-controlled. Normally closed, when there is no pressure difference between inlet and outlet, the electromagnetic force after switching on directly opens the pilot hole to connect the main valve, and the piston in turn lifts and the valve opens; When the inlet and outlet reach the starting pressure difference after switching on, the electromagnetic force is first. When the pilot hole is opened, the pressure in the upper chamber of the main valve piston falls, so that the pressure difference and the electromagnetic force are used to pull the main piston, and the valve opening opens; When the power supply is off, the pilot hole is closed by the spring reset, the upper chamber of the main piston is pressurized, and the main piston is pressed down, the valve closes. Normally open is the opposite of normally closed.


What is the function of the solenoid valve?

Solenoid valves are used in industrial control systems to adjust direction, flow, speed and other parameters of the medium. The solenoid valve can be combined with different circuits to achieve the desired control, and the control accuracy and flexibility can be guaranteed.

In the solenoid valve, there is a closed cavity with through holes in different positions, each hole is connected to a different oil pipe, the center of the cavity is a piston, and the two sides are two electromagnets.

Guangzhou HERUI has been focusing on solenoid valves for many years and is committed to providing perfect service to every industrial production customer.


  • Room 201-1, Building 1, No. 1196, Middle of Zhongshan Avenue, Tianhe District, Guangzhou, Guangdong, China
  • Phone:
    +86-18565131780
    +86-20-32380405
  • Guangzhou HERUI is a trading company, specialized in construction machinery, dedicated to spare parts of excavators,breakers, forklifts, bulldozers, heavy trucks...
  • Quick Links​​​​​​​
  • News
    What is a gear pump?

    ​The gear pump consists of two gears, the pump body and the front and rear covers to form two enclosed spaces. As the gears rotate, the volume of space on the side of the gear displacement increases from small to large, creating a vacuum to suck in the liquid, and the volume of space on the side of the gear engagement increases the larger it becomes smaller, and the liquid is pushed into the pipeline. The intake cavity and the ejection cavity are separated by the engagement line of the two gears. The pressure at the output of the gear pump depends solely on the resistance at the pump output.

    What do you know about the use of gear pumps?

    ​The gear pump is simple and compact in construction, small, light, good in manufacturability, cheap in price, strong in self-priming, insensitive to oil pollution, large in speed range, able to withstand shock loads, convenient in maintenance and reliable in operation. The gear pump is a rotary pump that depends on the change and movement of the work volume formed between the pump cylinder and the combing gear to transport liquid or put pressure on it.

    How to select a control valve?

    ​The control valve consists of two main assemblies: valve body assembly and actuator assembly (or actuator system), which are divided into four series: single seat series regulating valve, double seat series regulating valve, sleeve cylinder series regulating valve and automatic series regulating valve.

    How can we use the regulator correctly?

    The regulator compares the measured value of the parameters of the production process with the given value, and after the deviation is obtained, an output signal is generated according to a certain adjustment rule to push the actuator to eliminate the deviation, so that the parameter is kept near the given value or changes according to a predetermined rule. controller.

  • Contact Us​​​​​​​
     +86-15914340095